¹¤Òµ¼¶²úÆ·Éè¼Æ
ÎÞ¾åÊÒ±í¶ñÁÓ»·¾³£¬É豸²»±äÔËÐÐ
24¿ÚǧÕ×»ú¼Üʽ¹¤Òµ¼¶ÒÔÌ«Íø»¥»»»ú RG-IS5200-24GT4XS-UP-DC
ÃæÏò°²È«¡¢¸ßЧºÍ½ÚÄܵÄÉè¼ÆÀíÏëÍÆ³öµÄÐÂÒ»´úǧÕ×ÒÔÌ«Íø»¥»»»ú£¬×¨Îª¹¤Òµ»·¾³Éè¼Æ£»»ú¼ÜʽװÖã¬Çá±ã½Ã½Ý
Âú×㰼͹Ρ¢¿¹Õñ¶¯¡¢·ÀÀ×»÷µÈ¸´ÔÓ»·¾³ÐèÒª£¬ºÏÓÃÓÚÊÒ±í¼à¿Ø¡¢ÌØÊâÆøÏóǰÌáºÍÔì×÷Òµ£¬»¹¿É²¿ÊðÔÚ¸ê±Ú¡¢·Û³¾¿ÅÁ£´óµÄÐÂÄÜÔ´¹¤³§¡¢¼°ÑζÇÖÊ´µÄÑØº£µØÓòµÈ³¡¾°
ÀàÐÍ£º
²úÆ·¸öÐÔ£º
¹¤Òµ¼¶²úÆ·Éè¼Æ
ÎÞ¾åÊÒ±í¶ñÁÓ»·¾³£¬É豸²»±äÔËÐÐ
ÃæÏò°²È«¡¢¸ßЧºÍ½ÚÄܵÄÉè¼ÆÀíÏëÍÆ³öµÄÐÂÒ»´úǧÕ×ÒÔÌ«Íø»¥»»»ú£¬×¨Îª¹¤Òµ»·¾³Éè¼Æ£»»ú¼ÜʽװÖã¬Çá±ã½Ã½Ý
| ½Ó¿Ú¹æ¸ñ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| ¹Ì»¯ÒµÎñ½Ó¿Ú | 8¸ö10/100/1000BASE-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© | 8¸ö10/100/1000BASE-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© | 8¸ö10/100/1000BASE-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú£¬Ö§³ÖPoE/PoE+/PoE++£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© | 24¸ö10/100/1000BASE-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú, Ö§³ÖPoE/PoE+/PoE++£¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© |
| ¹Ì»¯ÖÎÀí½Ó¿Ú | 1¸öRJ45µÄConsole½Ó¿Ú | |||
| RS485½Ó¿Ú | 1¸öRS485½Ó¿Ú£¬Ö§³ÖModbusºÍ̸ | |||
| DIDO | 1·DI£¬1·DO | |||
| USB½Ó¿Ú | 1¸öUSB 2.0¶Ë¿Ú£¬Ö§³ÖUSBÅäÖÃÊèµ¼£¬Ö§³Öͨ¹ýUÅ̱£ÁôÈÕÖ¾¡¢µ¼³öÅäÖã¬Éý¼¶×°Öðü | |||
ϵͳ¹æ¸ñ
| ϵͳ¹æ¸ñ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| »¥»»ÈÝÁ¿ | 520Gbps/5.2Tbps | |||
| °üת·¢ÂÊ | 102Mpps | 183Mpps | ||
³ß´çÓë³ÁÁ¿
| ³ß´çÓë³ÁÁ¿ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| ²úÆ·³ß´ç£¨¿í×Éî׸ߣ© | 150mm×133mm×86mm | 150mm×133mm×86mm | 150mm×133mm×86mm | 442mm×220mm×43.6mm |
| ²úÆ·³ÁÁ¿ | 1.49kg | 1.5kg | 1.53kg | 2.85kg |
| ×°Ö÷½Ê½ | ×ÀÃæ×°Öá¢DINµ¼¹ì×°ÖᢱڹÒ×°Öà | ×ÀÃæ×°Öᢻú¼Ü×°ÖᢱڹÒ×°Öà | ||
µçÔ´Ó빦ºÄ
| µçÔ´Ó빦ºÄ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC | |
| µçÔ´½Ó¿Ú | ·ï»Ë¶Ë×Ó | ||||
| PoE¹©µç³ß¶È | ²»Ö§³Ö | ½Ó¿Ú1~8Ö§³ÖPoE¡¢PoE+¡¢PoE++£¨IEEE802.3af/at/bt£©¹©µç | ½Ó¿Ú1~24Ö§³ÖPoE¡¢PoE+¡¢PoE++£¨IEEE802.3af/at/bt£©¹©µç | ||
| PoEÊä³ö¹¦ÂÊ | ²»Ö§³Ö | Õû»ú×î´óPoEÊä³ö¹¦ÂÊ£º480W PoE½Ó¿Ú×î´ó¹©µç£º15.4W(PoE)£¬30W(PoE+)£¬60W/90W(PoE++) ×¢Ã÷£º RG-IS5200-8GT4XS-UP-DCÅäÖÃIPA240-PµçÔ´×î´óÖ»ÄÜÌṩ210WµÄPoEÊä³ö RG-IS5200-24GT4XS-UP-DCÅäÖÃIPA240-PµçÔ´×î´óÖ»ÄÜÌṩ200WµÄPoEÊä³ö ÏÖʵµÄPoE´øÔØÊýÁ¿£¬ÇëÆ¾¾ÝµçÔ´Ä£¿é¿ÉÓÃ×ܹ¦Âʼ°PoEÉ豸ÏÖʵ¹¦ÂÊÍÆËã¡£ |
|||
| µçÔ´ÊäÈë | »¥»»£¨AC£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º100V~240V AC£¬50/60Hz ×î´óÊäÈëµçѹ£º90V~264V AC£¬50/60Hz ¶î¶¨ÊäÈëµçÁ÷£º0.6A ¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º240V DC ×î´óÊäÈëµçѹ£º204V~288V DC ¶î¶¨ÊäÈëµçÁ÷£º0.3A |
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º12V~48V DC ×î´óÊäÈëµçѹ£º9.6V~60V DC ¶î¶¨ÊäÈëµçÁ÷£º2A~0.5A |
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º56V DC ×î´óÊäÈëµçѹ£º54~57V DC£¨Ö§³ÖPoE/PoE+/PoE++£©»ò48V DC£¨½öÖ§³Ö PoE£© ¶î¶¨ÊäÈëµçÁ÷£º10A |
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺 ¶î¶¨ÊäÈëµçѹ£º12VDC¡¢56V DC ²»Ö§³ÖPoE£º12V DC ½öÖ§³ÖPoE¹©µç£º48V DC Ö§³ÖPoE/PoE+/PoE++¹©µç£º54~57V DC ×î´óÊäÈëµçѹ£º9.6~60V DC ¶î¶¨ÊäÈëµçÁ÷£º10A£¨56Vdc£©¡¢4A£¨12Vdc£© |
|
| Õû»ú×î´ó¹¦ºÄ | 16.8W | 19.8W | 23.8W (ÎÞPoE¸ºÔØ) 503.8W (PoEÂúÔØ) |
12VÖ±Á÷µçÔ´ÊäÈ룺 36.8W 56VÖ±Á÷µçÔ´ÊäÈ룺 35.5W (ÎÞPoE¸ºÔØ) 515.5W (PoEÂúÔØ) |
|
| »·¾³Óë¿¿µÃסÐÔ | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| ·À³¾·ÀË®µÈ¼¶ | IP41£¬Í¨¹ýÑ¡ÅäIS52-shield¿ÉÖ§³ÖIP55·À»¤µÈ¼¶ ×¢Ã÷£ºÂã»úÏÂIP41·À»¤ÄÜÁ¦ÒªÇóÇ°Ãæ°å¶Ë¿Ú²»ÏòÉÏ×°Öà |
IP40 | ||
| ·ÀÀ× | ACµçÔ´½Ó¿Ú£º¹²Ä£6kV/²îÄ£6kV£¨BÅоݣ© ÒµÎñ½Ó¿Ú£º¹²Ä£10kV/²îÄ£500V(RÅоÝ) |
|||
| ¹¤×÷ÎÂ¶È | ¹¤×÷»·¾³Î¶ȣº(0m¡«1800m º£°Î£¬ÅäÌ×¹¤Òµ¼¶¹âÄ£¿é) –40°C¡«+65°C£¨×°ÖÃÔÚÃÜ·â¹ñ£© –40°C¡«+70°C£¨×°ÖÃÔÚ͸·ç¹ñ£¬Í¸·ç·ç¿ìÖÁÉÙΪ 80LFM £¨Line Feet Minute£©) –40°C¡«+75°C£¨×°ÖÃÔÚ×Ô´øµçÉȵÄ͸·ç¹ñ£¬Í¸·ç·ç¿ìÖÁÉÙΪ 200LFM£© ×¢Ã÷£ºÔÚº£°Î1800m~5000mÁìÓòÄÚ, º£°ÎÿÉý¸ß220m£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£ ´æ´¢»·¾³Î¶ȣº–40¡æ~+85¡æ |
¹¤×÷»·¾³Î¶ȣº(0m¡«1800m º£°Î£¬ÅäÌ×¹¤Òµ¼¶¹âÄ£¿é) –40°C¡«+60°C£¨×°ÖÃÔÚÃÜ·â¹ñ£¬RG-IS5200-8GT4XS-UP-DCÊä³öPoE¹¦ÂÊ480W£© –40°C¡«+65°C£¨×°ÖÃÔÚÃÜ·â¹ñ£¬ RG-IS5200-8GT4XS-UP-DCÊä³öPoE¹¦ÂÊ210W£¬RG-IS5200-24GT4XS-UP-DC£© –40°C¡«+70°C£¨×°ÖÃÔÚ͸·ç¹ñ£¬Í¸·ç·ç¿ìÖÁÉÙΪ 80LFM £¨Line Feet Minute£©) –40°C¡«+75°C£¨×°ÖÃÔÚ×Ô´øµçÉȵÄ͸·ç¹ñ£¬Í¸·ç·ç¿ìÖÁÉÙΪ 200LFM£© ×¢Ã÷£ºÔÚº£°Î1800m~5000mÁìÓòÄÚ, º£°ÎÿÉý¸ß220m£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£ ´æ´¢»·¾³Î¶ȣº–40¡æ~+85¡æ |
||
| ʪ¶È | ¹¤×÷»·¾³Êª¶È£º10%RH~90%RH ´æ´¢»·¾³Êª¶È£º5%RH~95%RH |
|||
| º£°Î | ¹¤×÷º£°Î£º0~5000m ´æ´¢º£°Î£º0~5000m |
|||
| ¾ùÔÈÎÞ¹ÊÕϹ¦·ò£¨MTBF£© | 40¡æÒÔÏ´óÓÚ300000Ó×ʱ£¨Ô¼34Ä꣩ | |||
| µçÉÈ | ÎÞµçÉÈ£¬ÌìȻɢÈÈ | |||
| µçÔ´¼à¿Ø | ²»Ö§³Ö | µçÔ´ÔÚλ¼ì²â£ºÖ§³Ö | ||
| ÎÂ¶È¼à¿Ø | Ö§³ÖÎÂ¶È¼à¿Ø¡¢Î¶ȸ澯¡¢¹ýα£»¤ | |||
| ¾²µç¿¹ÈÅ | ³ß¶È²âÊÔ½Ó´¥/¿ÕÆø£º6kV/8kV ÄÍÊÜÐÔ½Ó´¥/¿ÕÆø£º8K/15K |
|||
| ¹¤Æµ´Å³¡ | ²»±ä³ÖÐø´Å³¡£º30A/m ¶Ìʱ×÷Óôų¡£º300A/m |
|||
| ´«µ¼¿¹ÈÅ | »úÄÜÅоݣºA ɨƵÁìÓò£º0.15¡«80MHz µ÷Ô죺80%AM¡¢1kHzÕýÏÒ²¨ ACµçÔ´½Ó¿Ú£º3V ÒµÎñ½Ó¿Ú£º3V DI½Ó¿Ú/DO½Ó¿Ú/RS485½Ó¿Ú £º3V |
»úÄÜÅоݣºA ɨƵÁìÓò£º0.15¡«80MHz µ÷Ô죺80%AM¡¢1kHzÕýÏÒ²¨ ÊÊÅäÆ÷ACµçÔ´½Ó¿Ú£º3V ÒµÎñ½Ó¿Ú£º3V DI½Ó¿Ú/DO½Ó¿Ú/RS485½Ó¿Ú £º3V |
||
| µçѹµøÂä | ACµçÔ´¿Ú£º ¡ñ Ôü×Òµçѹ70£¥£¬Î¬³Ö25ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ôü×Òµçѹ0£¥£¬Î¬³Ö0.5ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ôü×Òµçѹ0£¥£¬Î¬³Ö1ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ôü×Òµçѹ0£¥£¬Î¬³Ö250ÖÜÆÚ£¨ÅоÝC£© |
ÊÊÅäÆ÷ACµçÔ´½Ó¿Ú£º ¡ñ Ôü×Òµçѹ70£¥£¬Î¬³Ö25ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ôü×Òµçѹ0£¥£¬Î¬³Ö0.5ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ôü×Òµçѹ0£¥£¬Î¬³Ö1ÖÜÆÚ£¨ÅоÝB£© ¡ñ Ôü×Òµçѹ0£¥£¬Î¬³Ö250ÖÜÆÚ£¨ÅоÝC£© |
||
| г²¨ | ƾ¾ÝIEC61000-3-2£¬GB17625.1£¬Âú×ãAÀàÉ豸ÏÞÖµ | |||
| ÈÏÖ¤ÓëÂÉÀý | RG-IS5200-8GT4XS | RG-IS5200-8GT4XS-DC | RG-IS5200-8GT4XS-UP-DC | RG-IS5200-24GT4XS-UP-DC |
| EMCÂÉÀý | GB 9254-2008, CLASS A | |||
| Èí¼þ¹æ¸ñ | |
| MACµØÖ·±í | Ö§³Ö¾²Ì¬MACµØÖ· Ö§³ÖMACµØÖ·¹ýÂË |
| 802.1Q VLAN | Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN Ö§³ÖMAC based VLAN Ö§³ÖProtocol based VLAN Ö§³ÖPrivate VLAN Ö§³ÖVoice VLAN Ö§³ÖIP subnet-based VLAN Ö§³ÖGVRP |
| QinQ | Ö§³Ö¸ù»ùQinQ Ö§³Ö½Ã½ÝQinQ |
| ¶þ²ã»·Íø¼¼Êõ | Ö§³ÖG.8032¹ú¼Ê³ß¶È»·ÍøºÍ̸ERPS£¬¿ÉÓëÆäËûÖ§³Ö¸ÃºÍ̸µÄ²úÆ·¼æÈÝ Ö§³ÖSTP Ö§³ÖRSTP Ö§³ÖMSTP |
| ¶Ë¿Ú¾ÛºÏ | Ö§³ÖÁ÷Á¿Æ½ºâ·½Ê½ Ö§³ÖLACP¾²Ì¬¡¢¶¯Ì¬¾ÛºÏ Ö§³Ö¿çVSU AP |
| Mirror | Ö§³Öͨ³£ÒµÎñ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ö÷ÕÅ¶Ë¿Ú Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢·´Éä¿ÚÒ»¶Ô¶àµÄ¾µÏñ£¬Ö§³ÖRSPAN Ö§³Ö¿çÉ豸µÄÁ÷Á¿¾µÏñ |
| DHCP | Ö§³ÖDHCP Server Ö§³ÖDHCP Client Ö§³ÖDHCP Snooping Ö§³ÖDHCP Relay Ö§³ÖIPv6 DHCP Snooping Ö§³ÖIPv6 DHCP Client Ö§³ÖIPv6 DHCP Relay |
| VSU¸öÐÔ | Ö§³ÖVSUÐé¹¹»¯¼¼Êõ Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ Ö§³Öͨ¹ý³ß¶ÈÒµÎñ»°±úÏÖÐé¹¹»¯ |
| ÁãÅäÖà | Ö§³ÖCWMP(TR069)ºÍ̸³ß¶ÈºÍ̸ |
| IP·ÓÉ | IPv4/IPv6 ¾²Ì¬Â·ÓÉ RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3 Routing Policy |
| ACL | Ö§³Ö³ß¶ÈIP ACL Ö§³ÖÀ©´óIP ACL Ö§³ÖMACÀ©´óACL Ö§³Ö»ùÓÚ¹¦·òACL Ö§³Öר¼Ò¼¶ACL Ö§³ÖACL80 Ö§³ÖIPv6 ACL Ö§³ÖÈ«¾ÖACL Ö§³ÖACL³Á¶¨Ïò |
| IPv6»ù´¡ºÍ̸ | IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖºÍ̸£¨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ |
| QoS | Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì Ö§³Ö802.1p/DSCP/ IP precedenceÁ÷Á¿·ÖÀà ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢SP+WRR¡¢SP+DRR¶ÓÁе÷¶È |
| °²È«¸öÐÔ | Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x Ö§³ÖMAB Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤ Ö§³ÖARP Check Ö§³ÖDAI Ö§³Ö·ÀÍø¹ØARPºýŪ Ö§³Ö¹ã²¥·ç±©ÒÖÔì ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤ Ö§³ÖRADIUS ºÍ TACACS+ Ö§³ÖBPDU Guard Ö§³ÖIP Source Guard Ö§³ÖCPP¡¢NFPP Ö§³Ö¶Ë¿Ú±£»¤ |
| ÖÎÀí¸öÐÔ | SNMP¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢sFLOW |