GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-IF2920-24GT4MS-P
RG-IF2920-24GT4MS-P
RG-IF2920-24GT4MS-P
RG-IF2920-24GT4MS-P
RG-IF2920-24GT4MS-P
RG-IF2920-24GT4MS-P
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

24¿ÚǧÕ×POEÒÔÌ«²Ê¹âÍøÂ绥»»»ú£¬4¸ö2.5G¹â¿Ú£¬ RG-IF2920-24GT4MS-P

¿ÉÀûÓÃÔÚ½ÌÓý¡¢Ò½ÁÆ¡¢Ôì×÷¡¢°ì¹«¡¢ÆóÒµ¼¶ºÍÉÌÓÿͻ§µÄÖǻ۽ÌÊÒ¡¢¶àýÌå½ÌÊÒ¡¢°ì¹«ÊÒ¡¢ÕïÊÒ²¡·¿¡¢Î¢ÐÍ·ÖÖ§»ú¹¹¡¢³ö²úÏß»ų́µÈÆäËüÅäÏßÊÜÏ޵Ļ·¾³ÖУ¬ÎªÎÞÏß¡¢³¬ÇåÊý×ÖÊÓÆµÉãÏñÍ·¡¢ÖÇÄܵç×Ó´²Í·ÆÁ¡¢AIÖʼ촫¸ÐÆ÷µÈº£Á¿ÎïÁªÖÕ¶ËºÍÆäËûIPÐÅÏ¢µãλÌṩ¾Í½ü½ÓÈëÒÔ¼°³¬´ó´ø¿í

²úÆ·¸öÐÔ£º

  • ¹âÏËÈëÊÒ¶ÀÏí¸ß´ø¿í£¬24¸öǧÕ×ÒÔÌ«Íø¿Ú£¬4¸ö2.5G¹â¿ÚÓÃÓÚÉÏÁª£¬Ö§³ÖPOE/POE+
  • ¿¿µÃסÐÔÉý¼¶£¬¶ÀÁ¢¹âÄ£¿éÉè¼Æ£¬Êý¾Ýת·¢¸ü²»±ä
  • ½ðÊô±í¿ÇºÍ½ðÊôÍø¿ÚÉè¼Æ£¬¾ß±¸IK05·À»¤ÄÜÁ¦
  • ÒÔÌ«²Ê¹âÍøÂçÔËά£¬ÖÎÀíµ¥Ò»ÓÐЧ£¬ÍøÂ簲ȫ¿¿µÃס
µ±¼´Õ÷ѯ

ÆóÒµ¼¶ÒÔÌ«²Ê¹â»¥»»»ú RG-IF2920-24GT4MS-P

ÒÔÌ«²Ê¹âÍøÂçѡȡÒÔÌ«Íø¼Ü¹¹ÊµÏֲʹⲿÊð£¬ÏÂÐÐǧÕ×½ÓÈë+2.5GÉÏÐУ¬Ò»»úÆ¥Åä¸÷Àà´«¸ÐÆ÷+AIÖʼìÉãÏñÓŵȸߴø¿í¶à¶Ë¿Ú³¡¾°

GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¿¿µÃסÐÔÉý¼¶£¬¶ÀÁ¢¹âÄ£¿éÉè¼Æ£¬Êý¾Ýת·¢¸ü²»±ä
´«Í³POL¹â¹æ»®£¬ONUÆ÷¼þʹÓðåÔØ¹âÄ£¿éÉè¼Æ£¬ÐźÅÖÊÁ¿Ó뺸½Ó¿¿µÃס´æÔÚÆúÈ¡ÎÊÌ⣬¹ÊÕÏÂÊÍùÍù¹ý¸ß£»ÒÔÌ«²Ê¹âÍøÂçѡȡµã¶Ôµã´«Ê䣬Ìṩ¸üΪ¿¿µÃסµÄ¶ÀÁ¢¹âÄ£¿éÉè¼Æ£¬¸ßÖÊÁ¿ÐźŴ«Êä²»Êܱí½ç×ÌÈÅ£¬Êý¾Ýת·¢¸ü²»±ä
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
Æ·¿ØÑÏ¿Á£¬°²ÐÄ֮ѡ
ѡȡ½ðÊô±í¿ÇºÍ½ðÊôÍø¿ÚÉè¼Æ£¬¾ß±¸IK05·À»¤ÄÜÁ¦£¬ÔÚÊܵ½±í½ç»úеÅöײʱÉ豸ȫ±í¿Ç¿ÉÄܱ£»¤É豸ÄÚ²¿²»ÊÜÓ°Ï죬²¢±£ÕÏÉ豸¿ÉÄÜÕý³£ÔËÐÐ ¡£
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
´îÅäSDN½ÚÔìÆ÷ £¬ÊµÏÖ¼«¼òÔËά£¬ÔËάÖÎÀíµ¥Ò»¸ßЧ
ͳһƽ̨ÖÎÀíÓëʵʱ¼à¿ØÍøÂç״̬£¬Õë¶Ô¹âÍøÂç½øÐÐÓû§ÂÄÀúÈ«Á´¶´²ì¡¢ÖÇÄÜ·ÖÎöÕï¶Ï£¬±£ÏÕÒµÎñÂÄÀú

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

ϵͳ¹æ¸ñ

²úÆ·ÐͺŠRG-IF2920-24GT4MS RG-IF2920-48GT4MS RG-IF2920-24GT4MS-P
»¥»»ÈÝÁ¿ 672Gbps/6.72Tbps
°üת·¢ÂÊ 179Mpps 219Mpps 179Mpps

½Ó¿Ú¹æ¸ñ

²úÆ·ÐͺŠRG-IF2920-24GT4MS RG-IF2920-48GT4MS RG-IF2920-24GT4MS-P
¹Ì»¯ÒµÎñ½Ó¿Ú 24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/2.5GE SFP½Ó¿Ú
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/2.5GE SFP½Ó¿Ú
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/2.5GE SFP½Ó¿Ú
¹Ì»¯ÖÎÀí½Ó¿Ú 1¸öRJ45 Console½Ó¿Ú£¬1¸öUSB½Ó¿Ú
ÏßÀÂÈȲå°Î ÒµÎñ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö

³ß´çÓë³ÁÁ¿

²úÆ·ÐͺŠRG-IF2920-24GT4MS RG-IF2920-48GT4MS RG-IF2920-24GT4MS-P
²úÆ·³ß´ç£¨¿í¡ÁÉî¡Á¸ß£© 440.0mm x 165.0mm x 43.6mm 440mm x 260mm x 44mm 440mm x 220mm x 44mm
»ú¼Ü³ß´ç 1RU 1RU 1RU
²úÆ·³ÁÁ¿ 1.85 kg 2.8 kg 2.9 kg
×°Ö÷½Ê½ ±Ú¹Ò/»ú¼Ü/»ú¹ñ ±Ú¹Ò/»ú¼Ü/»ú¹ñ ±Ú¹Ò/»ú¼Ü/»ú¹ñ

µçÔ´Ó빦ºÄ

²úÆ·ÐͺŠRG-IF2920-24GT4MS RG-IF2920-48GT4MS RG-IF2920-24GT4MS-P
µçÔ´ 1¸ö¹Ì»¯µçÔ´
Õû»ú×î´ó¹¦ºÄ 15.6W 30W 23W (²»´øPoE¸ºÔØ)
393W (PoEÂúÔØ)
¶î¶¨ÊäÈëµçѹ 100V AC~240V AC£¬50~60Hz
×î´óÊäÈëµçѹ 90V AC~264V AC£¬47~63Hz
PoE½Ó¿Ú ²»Ö§³Ö ²»Ö§³Ö Ö§³ÖPoE/PoE+

»·¾³Óë¿¿µÃסÐÔ

²úÆ·ÐͺŠRG-IF2920-24GT4MS RG-IF2920-48GT4MS RG-IF2920-24GT4MS-P
µçÉÈ ÎÞµçÉÈ 2¸ö¹Ì»¯µçÉÈ 2¸ö¹Ì»¯µçÉÈ
É¢ÈÈ ÌìȻɢÈÈ ·çÀäÉ¢ÈÈ ·çÀäÉ¢ÈÈ
³£ÎÂÔëÉù ÎÞµçÉÈ ¡Ü37dB ¡Ü39dB
µçÉÈÖÇÄܵ÷¿ì ²»Éæ¼° Ö§³Ö Ö§³Ö
¹¤×÷ÎÂ¶È 0¡æ~45¡ãC£¨0~1800mº£°Î£©
´æ´¢ÎÂ¶È -40¡ãC~70¡ãC
ÎÂ¶È¼à¿Ø Ö§³Ö
ζȸ澯 Ö§³Ö
¹ýα£»¤ Ö§³Ö
¹¤×÷ʪ¶È 10%RH~90%RH£¨ÎÞÄý¹Ì£©
´æ´¢Êª¶È 5%RH~95%RH£¨ÎÞÄý¹Ì£©

Èí¼þ¹æ¸ñ

²úÆ·ÐͺŠRG-IF2920-24GT4MS£¬RG-IF2920-48GT4MS£¬RG-IF2920-24GT4MS-P
STP Ö§³Ö
RSTP Ö§³Ö
MSTP Ö§³Ö
RLDP Ö§³Ö
MACµØÖ·±í Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖVoice VLAN
QinQ Ö§³Ö¸ù»ùQinQ
¶þ²ã»·Íø¼¼Êõ Ö§³ÖG.8032¹ú¼Ê³ß¶È»·ÍøºÍ̸ERPS£¬Çл»¹¦·ò¡Ü200ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃºÍ̸µÄ²úÆ·ÃÀÂú¼æÈÝ
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½Ê½
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Mirror Ö§³Öͨ³£ÒµÎñ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ö÷ÕŶ˿Ú
Ö§³ÖÒ»¶ÔÒ»¡¢Ò»¶Ô¶à¡¢¶à¶ÔÒ»µÄ¾µÏñ£¬Ö§³ÖRSPAN
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
IP·ÓÉ IPv4/IPv6¾²Ì¬Â·ÓÉ
Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ¡¢RIP¡¢RIPng¡¢OSPF¡¢OSPFv3ºÍ̸
ACL Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACL³Á¶¨Ïò
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì
Ö§³Ö802.1p/DSCPÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢WFQ¡¢SP+WFQ¡¢SP+WRR¡¢SP+DRR¡¢¶ÓÁе÷¶È
°²È«¸öÐÔ ¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUSºÍTACACS+
Ö§³ÖSSHºÍSSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
EEE Ö§³ÖIEEE 802.3az³ß¶ÈµÄEEE½ÚÄܼ¼Êõ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õÓ×¶Ë¿ÚÔڸý׶εŦºÄ£¬´ïµ½Á˽ÚÄܵÄÖ÷ÕÅ
ÖÎÀí¸öÐÔ SNMP¡¢CLI(Telnet/Console)¡¢Syslog/Debug¡¢NTP¡¢SNTP¡¢FTP¡¢TFTP¡¢Web
·¢Õ¹¾ßÌå²ÎÊý

³£¼ûÎÊÌâ

faq-none
ÔÝÎÞÎÊÌ⣬ÎÒÒªÌáÎÊ
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ ¡£©£¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ ¡£©£¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À ¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿