GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-E
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

48¿ÚǧÕ×µçÈý²ãÍø¹ÜÐͽÓÈ뻥»»»ú£¬4¸öÍòÕ×ÉÏÐпÚ£¬RG-S5310-48GT4XS-E

ÓÃÓÚ´óÐÍÍøÂçȫǧÕ×½ÓÈë

²úÆ·¸öÐÔ£º

  • ¶Ë¿ÚÀàÐÍ·á˶£¬48¸öǧÕ×ÒÔÌ«Íø¿Ú£¬4¸öÍòÕ×¹â¿ÚÓÃÓÚÉÏÁª
  • ¿É°Î²å˫ģ¿é»¯µçÔ´£¬ÊµÏÖ1+1ÈßÓà
  • Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬½Ã½Ý×éÍø»úÄÜÇ¿
  • ¶àÖÖÍøÂ簲ȫսÊõ£¬ÊµÊ±¼à²â£¬±£ÕÏÍøÂç²»±äÔËÐÐ
  • ¶à³ÁÍøÂçÖÎÀí·½Ê½£¬ ʵÏÖµ¥Ò»ÇáËɵÄÍøÂçÊØ»¤
µ±¼´Õ÷ѯ
Èí¼þºÍ̸
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¸ß¿¿µÃסÐÔ
VRRP
STP/RSTP/MSTP
RLDP
ERPS
BFD
VSU£¨Ðé¹¹»¯¼¼Êõ£©
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
Èý²ã·ÓɺÍ̸
Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ
Ö§³ÖRIP
RIPng
OSPFv2
OSPFv3
BGP4
BGP4+
IS-IS
Routing Policy
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÀûÓúÍ̸
DNS
DHCP Relay
DHCP Server
DHCP Client
Telnet
TFTP
FTP
NTP
SNTP
Netconf
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÖÎÀí¸öÐÔ
SNMP
Web
CLI(Telnet/Console)
RMON(1,2,4,9)
Syslog/Debug
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
°²È«¸öÐÔ
CPP
NFPP
DHCP snooping
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞ¿ì
Ö§³Ö·ÀÍø¹ØARPºýŪ
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³Ö¶Ë¿Ú±£»¤

ÍòÕ×ÉÏÁªÈý²ã½ÓÈ뻥»»»ú RG-S5310-48GT4XS-E

¿ÉÓÃÓÚ´óÐÍÆóÊÂÒµÔ°ÇøÄÚ¾ÖÓòÍøµÄȫǧÕ×½ÓÈ룬4¸öÍòÕ×¹â¿ÚÓÃÓÚÉÏÁª¸ß¿ì´«ÊäÊý¾Ý
48¸öǧÕ××ÔÊÊÓ¦ÒÔÌ«Íø¿Ú£¬Îª½ü¾àÀëÒµÎñÌṩ¸ß¿ìÓÃÍøÂÄÀú

¿ÉÈȲå°Î˫ģ¿é»¯µçÔ´£¬ÎªÁ´Â·Ìṩ˫³Á±£»¤

Ö§³Ö¿ÉÈȰβå˫ģ¿é»¯µçÔ´£¬ÊµÏÖ1+1ÈßÓ࣬ÈôÊÇÆäÖÐÒ»¸öµçÔ´³öÏÖ¹ÊÕÏ£¬ÁíÒ»¸öµçÔ´ÎÞ·ìÏνÓ£¬ÎªÁ´Â·Ìṩ˫³Á±£»¤

Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬½Ã½Ý×éÍø»úÄÜÇ¿

ºÁÃë¼¶¹ÊÕϸ´Ô­
¸ßÀ©´ó
¼ò»¯×éÍø
VSUÐ鹹ϵͳºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓÈçÓö¹ÊÕÏ£¬¿ÉºÁÃë¼¶Çл»Á´Â·£¬±£ÕÏÍøÂç²»¼ä¶Ï

¶àÖÖÍøÂ簲ȫսÊõ£¬ÊµÊ±¼à²â£¬±£ÕÏÍøÂç³ÖÐø×³ÊµÐÔ

ÌṩCPU±£»¤Õ½Êõ£¬½ÚÔì·¢ÍùCPUµÄ±¨ÎÄÀàÐͺÍÁ÷Á¿´óÓ×£¬±£»¤CPUÀûÓÃÂÊ
Ìṩ»ù´¡ÍøÂç±£»¤Õ½Êõ£¨NFPP£©£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§½øÐиôÀ룬±£ÕÏÍøÂ簲ȫ²»±ä

¶à³ÁÍøÂçÖÎÀí·½Ê½ ʵÏÖµ¥Ò»ÇáËɵÄÍøÂçÊØ»¤

ÖÎÀí¸öÐÔ
ÖÎÀí·½Ê½
¶ą̀É豸ÖÎÀí
Ö§³ÖRMON¡¢Syslog¡¢USB±¸·ÝÈÕÖ¾¸öÐÔ£¬±£ÏÕÈÕ³£ÓÃÍøµÄÕý³£Õï¶ÏÓëÊØ»¤

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

ÐͺŠRG-S5310-24GT4XS-E
RG-S5310-24GT4XS-P-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-P-E
RG-S5310-24SFP4XS-E RG-S5310-48SFP4XS-E
½Ó¿Ú¹æ¸ñ
¹Ì»¯ÒµÎñ½Ó¿Ú 24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú 48¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú 24¸öǧÕ×SFP¹â¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú 48¸öǧÕ×SFP¹â¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú
ϵͳ¹æ¸ñ
»¥»»ÈÝÁ¿ 1.36Tbps/13.6Tbps
°üת·¢ÂÊ 291Mpps/770Mpps 560Mpps/770Mpps 291Mpps/770Mpps 560Mpps/770Mpps
³ß´çÓë³ÁÁ¿
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 442.0mm x 420.0mm x 43.6mm
µçÔ´Ó빦ºÄ
¶î¶¨ÊäÈëµçѹ RG-S5310-24GT4XS-E¡¢RG-S5310-48GT4XS-E¡¢RG-S5310-24SFP4XS-E¡¢RG-S5310-48SFP4XS-E»¥»»£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹÁìÓò100V~240V£¬ÆµÂÊ50/60Hz£»

RG-S5310-24GT4XS-P-E¡¢RG-S5310-48GT4XS-P-EµçÔ´£¬»¥»»£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹÁìÓò200V~240V£¬ÆµÂÊ50/60Hz
×î´óÊäÈëµçѹ RG-S5310-24GT4XS-E¡¢RG-S5310-48GT4XS-E¡¢RG-S5310-24SFP4XS-E¡¢RG-S5310-48SFP4XS-E»¥»»£¨AC£©ÊäÈ룺
  • ×î´óµçѹÁìÓò90V~264V£¬ÆµÂÊ50/60Hz£»

RG-S5310-24GT4XS-P-E¡¢RG-S5310-48GT4XS-P-EµçÔ´£¬»¥»»£¨AC£©ÊäÈ룺
  • ×î´óµçѹÁìÓò176V~264V£¬ÆµÂÊ50/60Hz
Õû»ú¹¦ºÄ ·ÇPOE£º≤40W
POE£º<810W£¨PoEÂúÔØ£©£¬<85W£¨²»´øPoE¸ºÔØ£©
·ÇPOE£º≤55W
POE£º<1570W
£¨PoEÂúÔØ£©£¬<75W£¨²»´øPoE¸ºÔØ£©
≤85W ≤108W
»·¾³Óë¿¿µÃסÐÔ
¹¤×÷ÎÂ¶È 0¡æ~45¡æ
´æ´¢ÎÂ¶È -40¡æ~70¡æ
¹¤×÷ʪ¶È 10%~90%RH
´æ´¢Êª¶È 5%~95%RH
ͨѶ½Ó¿Ú·ÀÀ× 10KV£¨ÒµÎñ½Ó¿Ú£©
µçÉÈ 1¸ö¹Ì»¯µçÉÈ V3.XXÒÔϰ汾£º1¸ö¹Ì»¯µçÉÈ
V3.XX¼°ÒÔÉϰ汾£º2¸ö¹Ì»¯µçÉÈ
2¸ö¹Ì»¯µçÉÈ 2¸ö¹Ì»¯µçÉÈ
µçÉÈ¼à¿Ø Ö§³ÖµçÉȵ÷¿ì¼°µçÉȹÊÕϸ澯ְÄÜ

Èí¼þ¹æ¸ñ

ÐͺŠRG-S5310-24GT4XS-E
RG-S5310-24GT4XS-P-E
RG-S5310-48GT4XS-E
RG-S5310-48GT4XS-P-E
RG-S5310-24SFP4XS-E RG-S5310-48SFP4XS-E
L2¸öÐÔ Ö§³Ö¶þ²ãÁ´Â·¾ÛºÏ
Ö§³ÖSTP¡¢RSTP¡¢MSTP£¬MSTPÊ·ýÊýÁ¿65¸ö£¬³öÏÖÁ´Â·¹ÊÕϺ󣬸÷¸öÉ豸¿ÉÄܽøÐÐÌìÉúÊ÷µÄ³ÁÐÂÍÆËã
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö¸ù»ùQinQ
Ö§³Ö½Ã½ÝQinQ
ACL Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë±êÓï¡¢ºÍ̸ÀàÐÍ¡¢¹¦·òµÈ½Ã½Ý×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACL³Á¶¨Ïò
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢SP+WRR¡¢RED/WRED¶ÓÁе÷¶È
Mirror Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ
Ö§³ÖSPAN±¾µØ¾µÏñºÍRSPAN¡¢ERSPANÔ¶³Ì¾µÏñ
Ö§³Ö»ùÓÚÁ÷µÄ±¾µØ¡¢Ô¶³Ì¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
°²È«¸öÐÔ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞ¿ì
Ö§³Ö·ÀÍø¹ØARPºýŪ
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖIP SOURCE Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
»·ÍøºÍ̸ Ö§³ÖG.8032¹ú¼Ê³ß¶È»·ÍøºÍ̸ERPS£¬¿ÉÓëÆäËûÖ§³Ö¸ÃºÍ̸µÄ²úÆ·¼æÈÝ
PoE ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3afºÍ802.3atµÄ¹©µç³ß¶È
Ö§³Ö×Ô¶¯¡¢½ÚÄܵĹ©µçÖÎÀíģʽ
Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç
Ö§³Ö»ùÓÚ¹¦·òÕ½Êõ¶ÔPoE¶Ë¿Ú°´Ê±¸ßµÍµç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
×¢£º½öRG-S5310-24GT4XS-P-EºÍRG-S5310-48GT4XS-P-EÖ§³ÖPoEÓйØÖ°ÄÜ
IP·ÓÉ IPv4/IPv6 ¾²Ì¬Â·ÓÉ
RIP¡¢RIPng¡¢OSPFv2 ¡¢OSPFv3¡¢BGP¡¢BGP4+¡¢ISIS¡¢ISISv6£¬¶¯Ì¬Â·ÓÉÖÐÖ§³Ö·ÓɳÁ·Ö·¢£¬Ö§³ÖÕë¶Ô¶¯Ì¬Â·ÓɺÍ̸µÄMD5ÈÏÖ¤
Routing Policy
ECMP
IPv6»ù´¡ºÍ̸ IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖºÍ̸£¨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 Tracert¡¢IPv6×é²¥µÈ
×é²¥ Ö§³ÖIGMP v1£¬v2£¬v3
Ö§³ÖIGMP v1£¬v2ºÍv3 Snooping
Ö§³ÖPIM-DM£¬PIM-SM£¬PIM-SSM
SAVI Ö§³Ö·ÀNS/NA/RS/RA±¨ÎĺýŪְÄÜ
Ö§³Ö·À˽ÉèIPv6µØÖ·
Ö§³Ö»º´æ·¸·¨ÖÕ¶ËÐÅÏ¢
MPLS Ö§³ÖMPLS VPN
Ö§³ÖMPLS IPv6
VSU¸öÐÔ Ö§³ÖVSUÐé¹¹»¯¼¼Êõ
Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·°ó¸¿
Ö§³Öͨ¹ý³ß¶ÈÒµÎñ»°±úÏÖÐé¹¹»¯
VxLAN (ÊÚȨ֧³Ö)Ö§³ÖVXLAN, Ö§³ÖVXLANÇÅģʽ¡¢VXLAN·ÓÉģʽ£¬Ö§³ÖVXLAN½ÚÔìÆ½ÃæMP-BGP EVPN
¿¿µÃסÐÔ µçÔ´Ö§³Ö1+1ÈßÓ౸·Ý
Ö§³ÖBFD
Ö§³Ö»ùÓÚipv6µÄÍø¹ØÈȱ¸ºÍ̸(VRRPv3)
ÁãÅäÖà ֧³ÖCWMP(TR069)ºÍ̸³ß¶ÈºÍ̸
ÖÎÀí¸öÐÔ SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢Web¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢sFLOW¡¢¹«ÓÐÔÆÆ½Ì¨ÖÎÀí
·¢Õ¹¾ßÌå²ÎÊý

ÀûÓôîÅä

40/100G¹âÏËÏß
ÍòÕ×¹âÏËÏß
ǧÕ×Ë«½ÊÏß
match
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
µçÔ´(2)
¶¨Ãû¹æ¶¨(2)
»·Â·¼ì²â(2)
³ß´ç(1)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S5310-24GT4XS-EÖÐ-E´ú±íʲôÒâ˼£¿
ÓÐЧ 52 ÎÞÓà 10

ÐͺÅÃûÖÐE°µÊ¾ÔÚͬϵÁл¥»»»úÖлúÄܼÓÇ¿°æµÄÒâ˼¡£

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
»¥»»»úµÄ»·Â·¼ì²âÔõôʵÏÖµÄÄØ£¿
ÓÐЧ 518 ÎÞÓà 70

ͨ¹ýGA»Æ½ð¼××ÔÖ÷Ñз¢µÄÓÃÓÚ¼±¾ç¼ì²âÒÔÌ«ÍøÁ´Â·¹ÊÕϵÄÁ´Â·ºÍ̸——RLDP À´ÊµÏֵġ£
ͨ³£µÄÒÔÌ«ÍøÁ´Â·¼ì²â»úÔì¶¼Ö»ÊÇÀûÓÃÎïÀíÏνӵÄ״̬£¬Í¨¹ýÎïÀí²ãµÄ×Ô¶¯Ð­ÉÌÀ´¼ì²âÁ´Â·µÄÁ¬Í¨ÐÔ¡£
µ«ÊÇÕâÖÖ¼ì²â»úÔì´æÔڿ϶¨µÄ¾ÖÏÞÐÔ£¬ÔÚһЩÇé¿öÏÂÎÞ·¨ÎªÓû§Ìṩ¿¿µÃסµÄÁ´Â·¼ì²âÐÅÏ¢£¬ºÃ±ÈÔÚ¹âÏË¿ÚÉϹâÏ˽ӹÜÏß¶Ô½Ó´í£¬ÓÉÓÚ¹âÏËת»»Æ÷µÄ´æÔÚ£¬Ôì³ÉÉ豸¶ÔÓ¦¶Ë¿ÚÎïÀíÉÏÊÇlinkup µÄ£¬µ«ÏÖʵ¶ÔÓ¦µÄ¶þ²ãÁ´Â·È´ÊÇÎÞ·¨Í¨Ñ¶µÄ¡£ÔٺñÈÁ½Ì¨ÒÔÌ«ÍøÉ豸֮¼ä¼ÜÉè×ÅÒ»¸öÖÐÑëÍøÂ磬ÓÉÓÚÍøÂç´«ÊäÖмÌÉ豸µÄ´æÔÚ£¬ÈôÊÇÕâЩÖмÌÉ豸³öÏÖ¹ÊÕÏ£¬½«Ôì³ÉͬÑùµÄÎÊÌâ¡£
ÀûÓÃRLDP ºÍ̸Óû§½«Äܹ»·½±ã¼±¾çµØ¼ì²â³öÒÔÌ«ÍøÉ豸µÄÁ´Â·¹ÊÕÏ£¬Ô̺¬µ¥ÏòÁ´Â·¹ÊÕÏ¡¢Ë«ÏòÁ´Â·¹ÊÕÏ¡¢»·Â·Á´Â·¹ÊÕÏ¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿