GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-S5315-24MG6XS-UP-E
RG-S5315-24MG6XS-UP-E
RG-S5315-24MG6XS-UP-E
RG-S5315-24MG6XS-UP-E
RG-S5315-24MG6XS-UP-E
RG-S5315-24MG6XS-UP-E
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

ÐÂÒ»´ú24¿Ú2.5G¶à¿ìÂʽÓÈ뻥»»»ú  £¬Ö§³ÖPoE++  £¬10GÉÏÐÐ  £¬RG-S5315-24MG6XS-UP-E

ÓµÓа²È«¡¢¸ßЧ¡¢ÖÇÄܺͽÚÄܵÈÌØÉ«  £¬ºÏÓÃÓÚ´óÐÍÔ°ÇøÍøÂ硢óÒ×ϵͳÒÔ¼°¶àýÌåºÍ·þÎñÆ÷ȺµÄ¸ß¿ì½ÓÈë

²úÆ·¸öÐÔ£º

  • Ö§³Ö·á˶µÄ¶Ë¿Ú״̬  £¬Ìṩ100M/1000M/2.5G Base-T×ÔÊÊÓ¦ÒÔÌ«Íø¶Ë¿Ú  £¬Âú×ãWi-Fi 6ºÍWi-Fi 7 AP¸ß´ø¿íÒªÇó
  • Ö§³ÖÄ£¿é»¯Ë«µçÔ´  £¬µ¥¶Ë¿Ú×î¸ßÖ§³ÖPoE++ 90W¹©µç  £¬Õû»ú×î´óPoEÊä³ö1600W¹©µç
  • Ö§³ÖCPP/NFPP/RLDP/DHCP snooping¶à³Á°²È«·À»¤Õ½Êõ, ±£ÏÕÉ豸³ÖÐøÔËÐÐ  £¬ÍøÂç²»±ä²»µôÏß
  • Ö§³ÖVSUÐé¹¹»¯¼¼Êõ  £¬½Ã½Ý×éÍø»úÄÜÇ¿
  • µçÉÈÖÇÄܵ÷¿ì  £¬¶Ë¿Ú×Ô¶¯ÐÝÃß  £¬½ÚÄÜÇÒ½µºÄ
  • WIS/SDNµÈ¶àƽ̨ÊÊÅä  £¬ÍøÂçÔËά¿ÉÊÓ»¯
µ±¼´Õ÷ѯ

2.5G¶à¿ìÂʽÓÈ뻥»»»úRG-S5315-24MG6XS-UP-E

RG-S5315-EϵÁл¥»»»úÌṩ24¸ö100/1000/2500BASE-T½ÓÈë¿ÚºÍ6¸ö1G/2.5G/10G SFP+ÉÏÐйâ¿Ú  £¬Ñ¡È¡ÏȽøµÄÓ²¼þ¼Ü¹¹Éè¼Æ  £¬´îÔØGA»Æ½ð¼×ÍøÂçÐÂRGOS 12.XÄ£¿é»¯²Ù×÷ϵͳ  £¬Ìṩ¸ü¿ìµÄÓ²¼þ´¦ÖûúÄÜ¡¢¸ü±ã½ÝµÄ²Ù×÷ʹÓÃÂÄÀú¡£
¿´¶Ë¿Ú
¿´³ß´ç

2.5G´ø¿í  £¬Âú×ãWi-Fi 7 AP»ò¸ü¸ß´ø¿íÒªÇó  £¬Í»ÆÆÇ§Õׯ¿¾±

´Ó1GÉý¼¶µ½2.5G  £¬ÎÞÐè¸ü»»µçÀ¼´¿ÉÌá¸ß 2.5 ±¶  £¬ºÏÓÃÓÚWi-Fi 7 AP»ò¸ü¸ß´ø¿íÒªÇó  £¬²¢ÊµÏÖ¸üÁ÷³©µÄ4K/8KÊÓÆµ/Á÷ýÌå¡¢¸ßÇåÊÓÆµ»áÒéºÍ AR/VR ÀûÓá£

Ö§³ÖPoE++¹©µç  £¬µ¥¶Ë¿Ú¹¦Âʸߴï90W  £¬½Ã½ÝÊÊÅä¶àÖÖÖÕ¶ËÉ豸

¸Ã»¥»»»ú¿É×Ô¶¯¼ì²â²¢ÖÇÄÜ·ÖÅäPoEÉ豸ËùÐè×î¼Ñ¹¦ÂÊ  £¬µ¥¶Ë¿Ú×î¸ßÖ§³Ö90W£¨PoE++£©¹©µç  £¬Õû»úPoE¹©µç´ï1600W  £¬ÇáËÉÂú×ã°²·À¼à¿Ø¡¢Ô¶³Ì»áÒéϵͳ¡¢Wi-Fi 6E/7ÎÞÏß½ÓÈëµãµÈ¸ß¹¦ºÄ³¡¾°ÐèÒª¡£

ÈȲå°ÎÄ£¿é»¯Ë«µçÔ´  £¬Ö§³Ö1+1ÈßÓ๩µç

½¨ÉèË«µçÔ´Ä£¿é²å²Û  £¬Ö§³ÖÈȲå°Î¼°1+1ÈßÓàÅäÖà  £¬¼´±ãµçÔ´¸ü»»Ò²¿É±£ÏÕÒµÎñÔËÐв»¼ä¶Ï  £¬È·±£ÍøÂçÁ´Â·¸ß¿¿µÃסÐÔ¡£

RG-UNCÍ³Ò»ÍøÂçÖÐÐÄ  £¬¼«¼ò»¯Í³Ò»ÖÎÀí  £¬×Ô¶¯»¯ÇáËÉÔËά

ʵʱ¼à¿ØÍøÂç״̬  £¬Óû§ÂÄÀúÈ«Á´¶´²ì¡¢ÖÇÄÜ·ÖÎöÕï¶Ï  £¬È«·½Î»±£ÏÕÒµÎñÂÄÀú
Ö§³Ö¹âÁ´Â·¶Ëµ½¶ËÔËά  £¬¹âÍøÂç¿ÉÊÓ»¯¡¢¿ÉÖÎÀí¡¢¿É½ÚÔì¡£

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

ÐͺŠRG-S5315-24MG6XS-UP-E
½Ó¿Ú¹æ¸ñ
Ä£¿é²å²Û 2¸öµçÔ´Ä£¿é²å²Û
¹Ì»¯ÒµÎñ½Ó¿Ú 24¸ö100/1000/2500Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú  £¬6¸ö1/2.5/10GE SFP+½Ó¿Ú
¹Ì»¯ÖÎÀí½Ó¿Ú 1¸öRJ45µÄConsole½Ó¿Ú
USB½Ó¿Ú 1¸öUSB½Ó¿Ú
µçÔ´Ä£¿é RG-PA1000I-P-F
RG-PD600I-P-F
RG-PA600I-P-F
USBÈȲå°Î USB½Ó¿ÚÖ§³ÖÈȲå°Î
ÏßÀÂÈȲå°Î ËùÓнӿÚÖ§³ÖÈȲå°ÎÏßÀÂ
ϵͳ¹æ¸ñ
»¥»»ÈÝÁ¿ 1.36Tbps/13.6Tbps
°üת·¢ÂÊ 225Mpps/770Mpps
CPU MACÄÚÖÃË«ºË´¦ÖÃÆ÷  £¬µ¥ºËÖ÷Ƶ1GHz
Bootrom 16MB
Flash Memory 256MB
ÄÚ´æ 1GB
³ß´çÓë³ÁÁ¿
²úÆ·³ß´ç£¨¿í¡ÁÉî¡Á¸ß£© 442mm¡Á420mm¡Á43.6mm
»ú¼Ü³ß´ç 1U
²úÆ·³ÁÁ¿ 4.1kg
µçÔ´Ó빦ºÄ
µçÔ´ Ä£¿é»¯Ë«µçÔ´
µçÔ´ÈßÓà ÔÚË«802.3at»òË«802.3af¹©µçÏ  £¬Ö§³Ö¹©µçÈȱ¸ÈßÓà
µçÔ´ÈȲå°Î Ö§³Ö
µçÔ´ÊäÈë RG-PA600I-P-F»¥»»£¨AC£©ÊäÈ룺
¡ñ ¶î¶¨ÊäÈëµçѹ£º100V~240V AC  £¬50Hz~60Hz
¡ñ ×î´óÊäÈëµçѹ£º90V~264V AC  £¬47Hz~63Hz
¡ñ ×î´óÊäÈëµçÁ÷£º8A
RG-PA600I-P-F¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
¡ñ ¶î¶¨ÊäÈëµçѹ£º240V DC
¡ñ ×î´óÊäÈëµçѹ£º192V~288V DC
¡ñ ×î´óÊäÈëµçÁ÷£º4A
RG-PD600I-P-FÖ±Á÷£¨DC£©ÊäÈ룺
¡ñ ¶î¶¨ÊäÈëµçѹ£º-48V~-60V DC
¡ñ ×î´óÊäÈëµçѹ£º-38V~-75V DC
¡ñ ×î´óÊäÈëµçÁ÷£º20A
RG-PA1000I-P-F»¥»»£¨AC£©ÊäÈë1£º
¡ñ ¶î¶¨ÊäÈëµçѹ£º100V~130V AC  £¬50Hz~60Hz
¡ñ ×î´óÊäÈëµçѹ£º90V~143V AC  £¬47Hz~63Hz
¡ñ ×î´óÊäÈëµçÁ÷£º12A
RG-PA1000I-P-F»¥»»£¨AC£©ÊäÈë2£º
¡ñ ¶î¶¨ÊäÈëµçѹ£º200V~240V AC  £¬50Hz~60Hz
¡ñ ×î´óÊäÈëµçѹ£º180V~264V AC  £¬47Hz~63Hz
¡ñ ×î´óÊäÈëµçÁ÷£º8A
RG-PA1000I-P-FÖ§³Ö¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
¡ñ ¶î¶¨ÊäÈëµçѹ£º240V DC
¡ñ ×î´óÊäÈëµçѹ£º192V~288V DC
¡ñ ×î´óÊäÈëµçÁ÷£º8A
µçÔ´×î´óÊä³ö¹¦ÂÊ RG-PA1000I£º
¡ñ 100V~130V AC£º930W£»
¡ñ 200V~240V AC£º1000W£»
¡ñ 240V DC£º1000W£»
RG-PA600I£º
¡ñ 100V~240V AC£º600W£»
¡ñ 240V DC£º600W£»
RG-PD600I£º
¡ñ -48V~-60V DC£º600W£»
×¢Ã÷£º
¡ñ RG-PA600IµçÔ´Ö§³Ö¸ßѹֱÁ÷Ë«ÏòÊäÈë  £¬²»Ó÷ֱæÖ±Á÷ÊäÈëµÄÕý¸º¼«¡£
¡ñ »ú·¿Ê¹ÓøßѹֱÁ÷ÊäÈëʱ  £¬Ó¦½¨ÉèÖ§³Ö¸ßѹֱÁ÷ÊäÈëµÄPDU¡£
¡ñ Åäµç·½Ã潨Ò齨ÉèÖ±Á÷¿Õ¿ª£ºÉϵçʱ  £¬Ó¦ÏȽӺõçÔ´ÏßÔÙ´ò¿ªÖ±Á÷¿Õ¿ª£»Ïµçʱ  £¬Ó¦ÏȶϿª¿Õ¿ªÔٰεçÔ´Ïß¡£
Õû»ú¹¦ºÄ ¡Ü75W£¨²»´øPoE¸ºÔØ£©
<1675W£¨PoEÂúÔØ£©
°ÑÎÈ£ºµçÔ´ÈßÓàºÍÂúÔØ×´Ì¬µÄ¹©µç×¢Ã÷Ïê¼ûÓ²¼þÊÖ²á
PoE½Ó¿Ú È«ÊýRJ45¿Ú¾ùÖ§³ÖPoE/PoE+/PoE++ £¨IEEE802.3af/at/bt£©¹©µç
PoEÖ°ÄÜ Ö§³Ö×Ô¶¯¡¢½ÚÄܵĹ©µçÖÎÀíģʽ
Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç
Ö§³Ö»ùÓÚ¹¦·òÕ½Êõ¶ÔPoE¶Ë¿Ú°´Ê±¸ßµÍµç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
PoE¹©µçÏß¶Ô 4Ïß¶Ô£¨1-2,3-6,4-5,7-8Ïß¶Ô£©
PoEÊä³ö¹¦ÂÊ RG-PA600I-P-F£º470W£¨Ë«µçÔ´940W£©
RG-PD600I-P-F£º470W£¨Ë«µçÔ´940W£©
RG-PA1000I-P-F£º800W£¨Ë«µçÔ´1600W£©
»·¾³Óë¿¿µÃסÐÔ
ÎÂ¶È ¹¤×÷ζÈ0¡æ~45¡æ
´æ´¢Î¶È-40¡æ~70¡æ
ʪ¶È ¹¤×÷ʪ¶È10%RH~90%RH
´æ´¢Êª¶È5%RH~95%RH
º£°Î ¹¤×÷º£°Î£º0~5000Ã×
´æ´¢º£°Î£º0~5000Ã×
¾ùÔÈÎÞ¹ÊÕϹ¦·ò£¨MTBF£© >200000Ó×ʱ
µçÉÈ ¹Ì»¯2µçÉÈ
É¢ÈÈ ×ó²àǰ²à½ø·ç  £¬ºó²à³ö·ç
ÔëÉù ³£ÎÂÉùѹ£º
31.9dB£¨Ë«AC 600W PoE 30%¸ºÔØ£©
32.3dB£¨Ë«AC 1000W PoE 30%¸ºÔØ£©
µçÔ´¼à¿Ø »ñÈ¡µçÔ´ÐͺţºÖ§³Ö
»ñÈ¡ÔÚλ״̬£ºÖ§³Ö
¹ÊÕϸ澯£ºÖ§³Ö
µçÉÈ¼à¿Ø Ö§³ÖµçÉÈ×Ô¶¯µ÷¿ì
Ö§³ÖµçÉȹÊÕϸ澯
ÎÂ¶È¼à¿Ø ÎÂ¶È¼à¿Ø£ºÖ§³Ö
ζȸ澯£ºÖ§³Ö
¹ýα£»¤£ºÖ§³Ö
¾²µç¿¹ÈÅ ¿ÕÆø·Åµç£º8KV
½Ó´¥·Åµç£º6KV
·ÀÀ× ÒµÎñ½Ó¿Ú£º10KV
µçÔ´½Ó¿Ú£º¹²Ä£6KV  £¬²îÄ£6KV
ÀËÓ¿ ÒµÎñ½Ó¿Ú£º10kV
µçÔ´½Ó¿Ú£º6kV
ÈÏÖ¤ÓëÂÉÀý
°²È«ÂÉÀý GB 4943.1
EMCÂÉÀý GB/T 9254.1
Rohs ÇкÏRohs 6

Èí¼þ¹æ¸ñ

ÐͺŠRG-S5315-24MG6XS-UP-E
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö¸ù»ùQinQ
Ö§³Ö½Ã½ÝQinQ
ACL Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë±êÓï¡¢ºÍ̸ÀàÐÍ¡¢¹¦·òµÈ½Ã½Ý×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACL³Á¶¨Ïò
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢SP+WRR¶ÓÁе÷¶È
Mirror Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ
Ö§³ÖSPAN±¾µØ¾µÏñºÍRSPANÔ¶³Ì¾µÏñ
Ö§³Ö»ùÓÚÁ÷µÄ±¾µØ¡¢Ô¶³Ì¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
°²È«¸öÐÔ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞ¿ì
Ö§³Ö·ÀÍø¹ØARPºýŪ
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖIP SOURCE Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
»·ÍøºÍ̸ Ö§³ÖG.8032¹ú¼Ê³ß¶È»·ÍøºÍ̸ERPS  £¬¿ÉÓëÆäËûÖ§³Ö¸ÃºÍ̸µÄ²úÆ·¼æÈÝ
PoE ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af¡¢802.3atºÍ802.3btµÄ¹©µç³ß¶È
Ö§³Ö×Ô¶¯¡¢½ÚÄܵĹ©µçÖÎÀíģʽ
Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç
Ö§³Ö»ùÓÚ¹¦·òÕ½Êõ¶ÔPoE¶Ë¿Ú°´Ê±¸ßµÍµç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
IP·ÓÉ IPv4/IPv6 ¾²Ì¬Â·ÓÉ
RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3
Routing Policy
IPv6»ù´¡ºÍ̸ IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖºÍ̸£¨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ
SAVI Ö§³Ö·ÀNS/NA/RS/RA±¨ÎĺýŪְÄÜ
Ö§³Ö·À˽ÉèIPv6µØÖ·
Ö§³Ö»º´æ·¸·¨ÖÕ¶ËÐÅÏ¢
VSU¸öÐÔ Ö§³ÖVSUÐé¹¹»¯¼¼Êõ
Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·°ó¸¿
Ö§³Öͨ¹ý³ß¶ÈÒµÎñ»°±úÏÖÐé¹¹»¯
¿¿µÃסÐÔ µçÔ´Ö§³Ö1+1ÈßÓ౸·Ý
Ö§³ÖBFD
Ö§³Ö»ùÓÚIPv6µÄÍø¹ØÈȱ¸ºÍ̸(VRRPv3)
ÁãÅäÖà ֧³ÖCWMP(TR069)ºÍ̸³ß¶ÈºÍ̸
ÖÎÀí¸öÐÔ SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1  £¬2  £¬3  £¬9)¡¢Web¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢sFLOW
·¢Õ¹¾ßÌå²ÎÊý

ÀûÓôîÅä

40/100G¹âÏËÏß
ÍòÕ×¹âÏËÏß
2.5GË«½ÊÏß
match
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
l**** 2025Äê07ÔÂ10ÈÕ
RG-S5315-24MG6XS-UP-EÕâ¸ö»¥»»»úÖ§³Ö¶ÑµþÂð
ÓÐЧ 1 ÎÞÓà 1
Ö§³ÖµÄ¡£
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌâ  £¬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿