GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
RG-S2900-18GT2SFP-L
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

18¿ÚǧÕ×¶þ²ãÍø¹ÜÐͽÓÈ뻥»»»ú£¬Ç§Õ×ÉÏÐУ¬RG-S2900-18GT2SFP-L

¿í·ºÀûÓÃÓÚÆÕ½Ì¡¢Ã³Ò׵زú¡¢Ö°½Ì¡¢ÆóÒµµÈÊг¡£¬Âú×ã°ì¹«Íø¡¢Éè±¸ÍøµÅ×ÃÍøÐèÒª

²úÆ·¸öÐÔ£º

  • 18¸ö10/100/1000Base-TÒÔÌ«Íø¿Ú£¬2¸öǧÕ×SFP¹â¿Ú
  • ÌØÓеÄCPU±£»¤Õ½Êõ£¬É豸°²È«·À¹¥»÷
  • Ö§³ÖRLDP£¬¼±¾ç¼ì²âÍøÂç¹ÊÕÏ£¬ÎªÍøÂ簲ȫ±£¼Ý»¤º½
  • Ö§³ÖÈ«Íø¹Ü£¬É豸ÖÎÀíÇáËÉÒײÙ×÷
  • ÎÞµçÉÈ£¬ÌìȻɢÈÈ£¬¾²ÒôÇÒ½ÚÄÜ
µ±¼´Õ÷ѯ
Èí¼þºÍ̸
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¶þ²ãºÍ̸
STP/RSTP/MSTP
LACP
Ö§³ÖMAC¹ýÂ˵ØÖ·/¾²Ì¬µØÖ·
RLDP/LLDP
IGMP SNOOPING
802.1Q VLAN
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
°²È«¸öÐÔ
¹ýÂË·¸·¨µÄMACµØÖ·
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖÓ²¼þCPP
DHCP snooping
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÖÎÀí¸öÐÔ
SNMP
WebÖÎÀí
CLI(Telnet/Console)
Syslog/Debug
TFTP/NTP

8¿ÚǧÕ×Íø¹ÜÐÍ»¥»»»ú
RG-S2900-18GT2SFP-L

ÎªÍøÂç½ÓÈëÉ豸ÌṩǧÕ×µ½×ÀÃæµÄÀûÓã¬Ö§³Ö&ldquo;ǧÕ×ÒÔÌ«Íø¿Ú+ǧÕ×Íø¿Ú/¹â¿Ú&rdquo;×é
ºÏ£¬·½±ã½Ã½Ý×éÍø£¬Âú×ãóÒ׵زú¡¢¾Æµê¡¢ÖÐÓׯóÒµ¸÷Àೡ¾°×éÍøÐèÒª
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
»¥»»ÈÝÁ¿

336Gbps/3.36Tbps

 
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
°üת·¢ÂÊ

42Mpps/96Mpps

 
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
MACµØÖ·±íÈÝÁ¿

8K

ÌØÓеÄCPU±£»¤Õ½Êõ£¬É豸²»±ä¸ß¿¿µÃס£¬ÍøÂçÔËÐв»¼ä¶Ï

ÓµÓÐCPP¸öÐÔ£¨CPU Protect Policy£©£¬½ÚÔì·¢ÍùCPUµÄ±¨ÎÄÀàÐͺÍÁ÷Á¿´óÓ×£¬
È·±£Õý³£ºÍ̸±¨ÎĺÍÖÎÀí±¨ÎĵĴ¦Ö㬳ä·Ö±£»¤CPU²»±»·¸·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´¿÷Ëð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

¼±¾ç»·Â·¼ì²â£¨RLDP£©£¬ÍøÂ簲ȫ¸üÁ÷³©

Ö§³Ö¼±¾çÁ´Â·¼ì²âºÍ̸£¨RLDP£©£¬¼±¾ç·¢ÏÖ¶Ë¿Ú˽½ÓHubµÈÉ豸ÐγɵĻ·Â·£¬
²¢ÊµÊ±×÷³öÖÒ¸æÍ¨Öª¡¢¹Ø¹Ø¶Ë¿ÚµÈ´¦Ö㬴ӶøÔ¤·ÀÓÉÓÚ»·Â·Ôì³ÉµÄ¹ã²¥·ç±©£¬±£ÏÕÉ豸ºÍÁ´Â·°²È«
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

ÎÞµçÉÈ£¬ÌìȻɢÈÈ£¬¾²ÒôÓÖ½ÚÄÜ

ÎÞµçÉÈÉè¼Æ£¬ÌìȻɢÈÈ£¬½Ú¼óÉ豸ÄܺÄ£¬Í¬Ê±½µµÍÔëÒô´«È¾£¬
¸ü¾²ÒôµØÊµÏÖǧÕ×µ½×ÀÃæ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©
 
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
Å·ÃËRoHS³ß¶È
 
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¶Ë¿Ú×Ô¶¯ÐÝÃߣ¬½Ú¼óÄܺÄ

Ö§³Ö¶à·½Ê½Íø¹Ü£¬É豸ÖÎÀíÇáËÉÒײÙ×÷

WebÖÎÀí
¼æÈݵÚÈý·½Íø¹Üƽ̨
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

¿ÉѡȡWebÖÎÀí¡¢CLI(ºÅÁîÐнӿÚ)µÈ¶àÑù»¯µÄ±¾µØ»¯ÖÎÀíºÍÊØ»¤·½Ê½£¬É豸ÖÎÀíµ¥Ò»±ã½Ý

GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

Ö§³ÖSNMPºÍ̸£¬¿É¶Ô½ÓµÚÈý·½ÍøÂçÖÎÀíÆ½Ì¨£¬ÊµÏÖ¶Ô¶ą̀·ÖÆçÆ·ÅÆÉ豸µÄͳһÖÎÀí£¬ÍøÂçÔËάºÍÖÎÀí¸ü¸ßЧ

¼¼Êõ²ÎÊý

¼¼Êõ²ÎÊý

²úÆ·ÐͺÅ

RG-S2900-24GT4SFP/2GT-L

RG-S2900-18GT2SFP-L

RG-S2900-8GT2SFP-L

RG-S2900-24GT4SFP/2GT-P-L

RG-S2900-8GT2SFP-P-L

¹Ì¶¨¶Ë¿Ú

24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö100M/1G SFP¹â¿Ú£¬2¸ö¸´ÓõÄ10/100/1000M×ÔÊÊÓ¦µç¿Ú

18¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬2¸ö100M/1G SFP¹â¿Ú

8¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬2¸ö100M/1G SFP¹â¿Ú

24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö100M/1G SFP¹â¿Ú£¬2¸ö¸´ÓõÄ10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬Ö§³ÖPoE/PoE+Ô¶³Ì¹©µç£¬×î´ó¹©µç¹¦ÂÊ370W

8¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬2¸ö100M/1G SFP¹â¿Ú£¬Ö§³ÖPoE/PoE+Ô¶³Ì¹©µç£¬×î´ó¹©µç¹¦ÂÊ130W

¸ù»ù¸öÐÔ

»¥»»ÈÝÁ¿

336Gbps/3.36Tbps

°üת·¢ÂÊ

42Mpps/126Mpps

42Mpps/96Mpps

30Mpps/80Mpps

42Mpps/126Mpps

30Mpps/80Mpps

¶þ²ã¸öÐÔ

MAC

Ö§³Ö¹ýÂ˵ØÖ·

Ö§³Ö¾²Ì¬µØÖ·

Ö§³Ö8KµØÖ·±í

802.1Q VLAN

Ö§³Ö4K 802.1Q VLAN

Ö§³ÖPort based VLAN

AP

Ö§³ÖÁ÷Á¿Æ½ºâ·½Ê½¿ÉÅäÖÃ

Ö§³ÖLACP

°²È«¸öÐÔ

¹ýÂË·¸·¨µÄMACµØÖ·

ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤

Ö§³ÖÓ²¼þCPP

EEE

Ö§³ÖIEEE 802.3az ³ß¶ÈµÄ EEE½ÚÄܼ¼Êõ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õÓ×¶Ë¿ÚÔڸý׶εŦºÄ£¬´ïµ½Á˽ÚÄܵÄÖ÷ÕÅ

ÖÎÀí¸öÐÔ

SNMP¡¢CLI(Telnet/Console)¡¢Syslog/Debug¡¢NTP¡¢TFTP¡¢Web¡¢MACCŵ¿Í¹«ÓÐÔÆÆ½Ì¨ÖÎÀí

ÎïÀí¸öÐÔ

 

µçÔ´

»¥»»£¨AC£©ÊäÈ룺
¶î¶¨µçѹÁìÓò£º100V~240V
×î´óµçѹÁìÓò£º90V~264V
ƵÂÊ£º50/60Hz

×î´ó¹¦ºÄ

RG-S2900-24GT4SFP/2GT-L£º≤22W

RG-S2900-18GT2SFP-L£º≤17W

RG-S2900-8GT2SFP-L£º≤8W

RG-S2900-24GT4SFP/2GT-P-L£º≤430W£¨PoE£º370W£©

RG-S2900-8GT2SFP-P-L£º≤145W£¨PoE£º125W£©

PoE

¹©µçÉè¼ÆÖ§³ÖIEEE 802.3afºÍ802.3atµÄ¹©µç³ß¶È

×Ô´øÒ»¼ü²é¿´PoE¹©µç״ְ̬ÄܵÄPoE°´Å¥£¬Çá°´¼´¿É²é¿´É豸µ±Ç°µÄͨѶ״̬ºÍ¹©µç״̬£¬¶ÔÉ豸ĿǰµÄ¹¤×÷״̬ÁËÈçÖ¸ÕÆ

Ö§³Ö»ùÓÚ¹¦·òÕ½Êõ¶ÔPoE¶Ë¿Ú°´Ê±¸ßµÍµç

µçÉÈ

ÎÞµçÉÈ£¬ÌìȻɢÈÈ£¨³ý24¿ÚPoEÐͺţ©

ζÈ

¹¤×÷ζȣº-5¡æ~55¡æ

´æ´¢Î¶ȣº-40¡æ~70¡æ

ʪ¶È

¹¤×÷ʪ¶È£º10%~90%£¨·ÇÄý¹Ì£©

´æ´¢Êª¶È£º5%~95%£¨·ÇÄý¹Ì£©

·¢Õ¹¾ßÌå²ÎÊý

ÀûÓôîÅä

GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
µçÔ´(3)
É¢ÈÈ(2)
Íø¹ÜÐÍ»¥»»»ú(2)
»·Â·¼ì²â(1)
»ú¼Üʽ(1)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S2900-LϵÁл¥»»»úÊÇ·ñ±ØÒªÁíÅäµçÔ´ £¿
ÓÐЧ 28 ÎÞÓà 2

¸ÃϵÁл¥»»»ú¶¼²»±ØÒªµ¥ÅäµçÔ´£¬³ýÁËRG-S2900-8GT2SFP-LÊÇÊÊÅäÆ÷¹©µç£¬ÆäËûÐͺŶ¼Êǹ̻¯µ¥»¥»»µçÔ´¡£

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-2900-L»¥»»»úÖ§³ÖÍø¹ÜÂ𠣿
ÓÐЧ 25 ÎÞÓà 1

Ö§³Ö£¬RG-2900-LϵÁл¥»»»úÊÇÈ«Íø¹ÜÐÍ£¬Ö§³ÖSNMP¡¢CLI(Telnet/Console)¡¢Syslog¡¢NTP¡¢TFTP¡¢WebµÈ£¬ÍøÂçÊØ»¤ÇáËɵ¥Ò»¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ £¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖà £¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ £¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Òé £¿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿